CX-Thermo doesn't connect to my Temperature Controller

Updated May 03, 2022

Scenario

CX-Thermo cannot connect to your OMRON temperature controller. It's likely that the temperature controller can be seen through CX-Thermo, but a proper connection cannot be established.


Issue

Older versions of CX-Thermo have limited compatibility with newer temperature controllers.


Solution

In the CX-Thermo folder on your PC, check the readme file. This will list the OMRON temperature controllers that your version of CX-Thermo is compatible with.

For example, the readme file of CX-Thermo v4.69 shows the following compatibilities.

Devices supported by CX-Thermo Ver.4.69

===========================================

CX-Thermo supports the following temperature controller series:

 E5GC

 E5CC

 E5EC

 E5AC

 E5DC

 E5CC-T

 E5EC-T

 E5AC-T

 E5CD

 E5ED

 E5GN

 E5CN

 E5EN

 E5AN

 E5CN-H

 E5EN-H

 E5AN-H

 E5CN-HT

 E5EN-HT

 E5AN-HT

 E5ER

 E5AR

 E5ER-T

 E5AR-T

 E5ZN

 EJ1N-TC4

 EJ1N-TC2

 EJ1N-HFU

 EJ1G-TC4

 EJ1G-TC2

 EJ1G-HFU


If your temperature controller does not appear on the list in your readme file, upgrading your version of CX-Thermo is likely to resolve the issue.

In order to update your version of CX-Thermo, follow the procedure here.


Start a Conversation
This conversation is closed
Uploading...